AT PLUS SERIES wastewater treatment plants
Description
The small units (AT6 – AT20 PLUS) treat 0,6 to 2,7 m³ wastewater per day. Can be used for a summer house, a detached or two-bedroom house, a hotel, a boarding house, a restaurant, a camper and a campsite, a small production company, etc. AT PLUS series household wastewater treatment plants are intended for the purification of wastewater in places that cannot be connected to the urban sewage systems or in places where the construction of such a network would be economically unviable or extremely difficult to implement.

Vertical Process
1 Non-aerated chamber – labyrinth with vertical flow
2 Aerated chamber
3 Final clarification chamber
4 Integrated retention chamber
5 Internal recirculation
6 Sludge recirculation
7 Fine-bubble diffuser
8 Flow regulator

Horizontal Process
1. Pre-sludge chamber (anaerobic)
2. Sedimentation chamber
3. Activated sludge chamber (aerobic)
A. Filter device (filter)
B. Excess sludge and compressed air
C. Diffuser
D. Compressor hose
E. Air distributor
F. Inlet
G. Departure
AT PLUS SERIES wastewater treatment plants

ATC-P Model Series | 6 | 8 | 10 | 12 |
---|---|---|---|---|
Population equivalent | 6 | 8 | 10 | 12 |
Capacity (m³/day) | 0.9 | 1.20 | 1.50 | 1.80 |
Average daily load (kg/BOD₅) | 0.36 | 0.48 | 0.60 | 0.72 |
Excess amount of sludge produced (m³/year) | 1.46 | 1.90 | 2.29 | 2.74 |
Electricity expenditure (kWh/day) | 1.02 | 1.02 | 2.1 | 2.1 |
Weight (kg) | 110 | 120 | 120 | 160 |
H (mm) | 2250 | 2250 | 2250 | 2250 |
Ø (mm) | 1220 | 1400 | 1510 | 1660 |
H-inlet (mm) | 1600 | 1600 | 1600 | 1600 |
H-outlet (mm) | 1550 | 1550 | 1550 | 1550 |
Ø-inlet (mm) | 110 | 110 | 110 | 110 |
Ø-outlet (mm) | 110 | 110 | 110 | 110 |
Contact us
If you have any questions, please feel free to drop us a call or email us. Our team will get back to you as soon as possible.
Call: 045 810 148
Email: info@bioproireland.ie